Replacing a furnace or installing a new heat pump is only half the job. The quiet but essential half happens after the equipment is in place: inspection and verification. Good contractors build these checks into their workflow, local code officials often verify the installation, and utility providers sometimes add a final layer for gas or electrical safety. When these steps happen in the right order, a heating system runs safely, efficiently, and without surprises.
I’ve walked into plenty of homes where a brand-new unit performed poorly or tripped safety switches because the “final checks” never moved beyond a quick visual glance. The most reliable installs I’ve seen share a common thread: meticulous post-install inspections, documented readings, and a willingness to make small adjustments before the crew leaves the driveway. Here is what to expect, why it matters, and how to spot the difference between a cursory look and a thorough safety evaluation after a heating unit installation or a full heating replacement.
The first pass: utility and code compliance
Most municipalities require permits for heating system installation. That permit tees up a post-install inspection by a city or county official. The inspector’s focus tends to be code compliance and life safety, not brand-specific tuning or performance optimization. They verify clearances to combustibles, venting, gas piping, electrical bonding and grounding, and whether the equipment matches the permit. If you have a gas utility, a representative may arrive to lock in the meter set, perform a leak check, and, in some regions, verify combustion safety before restoring full service.
Building inspectors usually see several installations a day and spot patterns quickly. If a vent connector slopes the wrong way or a furnace sits on combustible material without an approved base, it draws attention. Do not be surprised if the inspector asks for manufacturer’s installation instructions. Code references often defer to the listed installation requirements, so having that booklet on site helps.
On a practical note, it’s smart to have someone available during this inspection. If the inspector requests a small correction, getting it done on the spot can avoid a reinspection fee and a day without heat.
Gas leak checks and regulator settings
For any gas-fired furnace or boiler, a leak check is not optional. A contractor should soap-test all threaded joints they touched and confirm the gas shutoff is accessible and oriented with the handle clearly indicating on and off. I keep a digital manometer in the truck and expect techs to record line pressure, manifold pressure, and, when applicable, the step-down regulator setting.
On natural gas, manifold pressure typically sits around 3.5 inches of water column for many residential furnaces. Propane often runs closer to 10 to 11 inches at the manifold, depending on the appliance. Those are starting points, not absolutes. The installation manual governs, and high-altitude settings or two-stage equipment can change targets. If no readings are written on a startup sheet, ask for them. Numbers matter because they tie combustion conditions to a documented baseline. Six months later, if an igniter starts to struggle or the flame sensor trips, those initial readings help separate a drift in supply pressure from a failing component.
I’ve seen one too many homes where a new appliance was starved because a long, undersized run of piping fed multiple appliances. A simple before-and-after pressure reading with the rest of the gas appliances running will expose that. It isn’t glamorous, but it prevents callbacks and, more important, unsafe conditions.
Combustion analysis and draft verification
Combustion analysis is the most revealing single test on a gas or oil unit. It is also the most skipped when time runs tight. A proper analysis involves inserting a probe into the flue test port and measuring oxygen, carbon monoxide, and draft. On sealed-combustion high-efficiency furnaces, you also want to verify proper combustion air intake and check for recirculation issues.
What are you looking for?
- A stable draft that matches the appliance design and venting category. Carbon monoxide levels in the flue that stay within manufacturer’s limits. For most gas furnaces in good condition, CO should be low, often under a few hundred parts per million undiluted in the flue. The goal is as low as practical while maintaining stable operation. Excess air in a reasonable band. Too much can chill the flame and lower efficiency; too little risks incomplete combustion.
On chimney-vented units, a smoke test for oil burners and a draft test at the breach are standard. On 90 percent-plus furnaces, pay special attention to condensate traps and vent terminations, since a trap without water can alter pressure readings and lead to nuisance shutdowns.
I like to see a printout or at least written results. Numbers pinned near the unit serve as a snapshot of healthy operation, and they become a tool for future service work.
Electrical safety and circuit protection
Even gas furnaces are fundamentally electrical devices. After any heating system installation, the electrical side deserves deliberate inspection. A licensed installer should confirm:
- The circuit’s overcurrent protection matches the nameplate. If the unit calls for a maximum 15-amp breaker and you see a 20-amp, that is wrong even if the wire gauge is 12 AWG. Manufacturers specify protection to safeguard control boards, motors, and wiring within the appliance. Proper polarity and grounding. A reversed hot-neutral can create odd behavior, especially with flame rectification systems that rely on microamp signals to prove flame. Wire splices live in approved enclosures, strain reliefs are in place at knockouts, and low-voltage and line-voltage conductors are separated where required.
Expect the tech to check voltage under load. It’s not enough to read 120 volts with no demand. Watch the meter while the blower ramps or the heat pump hits defrost. A weak neutral or loose connection shows up at those moments.
Venting, terminations, and clearances
Venting should be a visual slam dunk with a few measurable checks. Flue pipes need the correct material, slope, and supports. On Category I appliances using metal venting, look for a minimum upward slope toward the chimney or common vent and snug joints with proper screws. On condensing furnaces that use PVC or CPVC, the installer should follow the manufacturer’s vent length and elbow count limits and seal joints with the appropriate cement.
Outside, the termination matters. A concentric vent kit needs clearances to grade, windows, doors, and corners. If two pipes terminate separately, the exhaust should not blow directly into the intake. I’ve seen intakes get placed in recessed alcoves where wind creates a low-pressure pocket that pulls exhaust back in. That leads to high CO in the flue and nuisance lockouts. A quick smoke test at the termination on a windy day can save you from that headache.
Clearances around the unit are not negotiable. Service access panels need space, and combustibles must be kept at the manufacturer’s required distances. A tight closet install might pass a quick glance yet violate the required working clearance. You pay for that later in service costs when a tech has to remove a door frame just to replace a blower motor.
Condensate management and freeze protection
High-efficiency furnaces, 90 percent and above, make water. Heat pumps in cold climates make water during defrost. That water must leave the home without backing up or freezing. A proper inspection includes priming the trap, confirming a pitched drain line, and running enough water through the system to watch it carry away without leaks. When a neutralizer is required, the installer should route the drain through it and secure it so it can’t tip or spill media.
In basements or attics without gravity drainage, a condensate pump must be sized for lift and run length, not just plugged in and forgotten. Pumps fail, usually on the coldest night, when slime or debris clogs the check valve. A simple float switch wired to cut the call for heat in the event of a backup is inexpensive insurance. In unconditioned spaces, heat trace or routing inside conditioned space helps prevent freeze-ups that can flood a ceiling.
If your install is a heating replacement that swaps an 80 percent furnace for a 96 percent, the new need for condensate disposal often gets missed during quoting. Post-install is the wrong time to discover there is no drain route. An experienced crew reviews and tests this before leaving.
Airflow, static pressure, and return integrity
Airside problems ruin good equipment. I’ve seen brand-new variable-speed furnaces choke on undersized returns or kinked flex runs. Post-install, a tech should measure external static pressure with a manometer at the supply and return. Most residential furnaces are designed for a maximum of 0.5 inches of water column external static, sometimes 0.8 on certain models. The reading tells you whether the duct system supports the unit’s airflow needs.
If the pressure is high, the blower works harder, noise increases, and heat exchangers or coils run too hot or too cold. In a southern retrofit where a heat pump shares ductwork with an older, restrictive trunk, I often recommend a return upgrade or additional return drops. It isn’t glamorous, but it pays back in comfort and longer equipment life.
The filter rack deserves a look. If the new unit replaced a 1-inch builder-grade filter with a high-MERV media cabinet, verify the rack seals and that the door closes without gaps. Bypass air around a filter fouls the blower and coil quickly, and it defeats the purpose of a high-efficiency filter.
Thermostat calibration and controls commissioning
Controls are where homeowners feel the system daily. After heating unit installation, the contractor should set up equipment staging, heat pump balance points, fan profiles, and any lockouts. Smart thermostats add another layer. They need correct wiring, proper equipment selection during setup, and sometimes firmware updates.
If your system is dual fuel, with a heat pump paired to a gas furnace, the changeover temperature is a judgment call that blends energy cost, comfort, and the home’s heat loss. A common starting point is in the mid 30s Fahrenheit, adjusted based on electricity and gas rates and how the home feels at the lower edge. Good installers will explain the trade-offs and return for a tweak if the switch point feels off during a cold snap.
I like to see the thermostat reading compared to a known thermometer in the same location. A two-degree offset is not unusual and can be corrected in settings. Also confirm the cycles per hour or differential settings match the equipment type. Short cycling wears parts and wastes energy.
Safety devices: operation and documentation
Most modern furnaces include multiple safety switches: rollout switches near the burners, pressure switches on the inducer, high limit switches on the heat exchanger, and sometimes a condensate overflow switch. Heat pumps and air handlers bring defrost controls, low ambient kits, and pan switches. The post-install inspection should confirm each device is wired, secured, and responsive.
Technicians sometimes simulate faults to verify response. That can be as simple as lifting a pressure tube to watch the furnace lock out, then reconnecting and clearing codes. Others will temporarily interrupt a pan switch to verify the blower stops. The point is not to stress the unit but to prove safeties will do their job. If you see jumpers left in place or a dangling pressure tube, ask questions.
Documentation is the unsung hero. A startup sheet that lists gas pressure, static pressure, temperature rise, flue test results, and model and serial numbers becomes your proof of a thorough job. It also satisfies many warranty requirements and helps any future tech diagnose issues without guessing.
Temperature rise and heat exchanger protection
Every furnace nameplate lists an acceptable temperature rise, often a range such as 35 to 65 degrees Fahrenheit. The installer should measure supply and return air temperatures after the unit runs long enough to stabilize and record the difference. A rise that sits outside the range hints at airflow or firing rate problems. Too high a rise means not enough airflow or too much gas input; too low a rise can indicate over-ventilation or an underfired unit.
In the field, I’ve seen oversize filters, closed registers, and dirty coils push the rise high enough to trip the high limit after ten minutes of operation. The best time to discover this is day one, not after the first cold spell. If you upgraded to a variable-speed blower during a heating replacement, the tech can often adjust blower profiles to dial the rise into spec without duct modifications.
Heat pump specific checks: refrigerant circuit and defrost
For heat pumps, post-install safety checks extend to the refrigeration loop. That means leak testing with nitrogen and refrigerant-grade soap during the install, then an evacuation to 500 microns or below with a decay test before opening the refrigerant. After start-up, the tech should verify superheat and subcooling against the manufacturer’s chart at the current outdoor temperature. Those numbers confirm the charge is correct and the metering device is doing its job.
Defrost controls deserve attention. On a cold, damp day, outdoor coils frost over, and the unit must reverse briefly to defrost without overheating the indoor space. A sensor on the coil, a timer, or both governs this. The installer should confirm the defrost initiates and terminates appropriately and that auxiliary heat, whether electric strips or a gas furnace in a dual-fuel setup, stages in during defrost to keep the home comfortable.
Electrical heat strips carry significant current. The breaker and wire size must match the strip kit’s nameplate. Loose lugs inside air handlers are a known failure point. A torque screwdriver used at commissioning prevents scorch marks later.
Combustion air and mechanical room dynamics
Appliances need air. In tight homes, a sealed combustion furnace pulls its own combustion air through the intake pipe and avoids indoor air entirely. In older setups or with certain boilers and water heaters, the mechanical room draws from the home or from dedicated combustion air ducts. If the installer added a high-efficiency furnace but left a natural-draft water heater, the room’s pressure dynamics matter. Exhaust fans, clothes dryers, or a tight new exterior door can tip the balance and backdraft the water heater. A worst-case depressurization test, even a simplified one, adds confidence. Close interior doors, run the dryer and bath fans, then verify the water heater still drafts properly. A mirror at the draft hood that fogs or a smoke source that spills out is a red flag.
If duct leakage in the return side pulls the mechanical room negative, that can also induce backdrafting. Sealing return joints with mastic during installation is a quiet but significant safety step.
Carbon monoxide alarms and homeowner orientation
No safety inspection wraps without talking about carbon monoxide detectors. They should be placed outside sleeping areas and on each floor, with at least one near the path from the mechanical room to the living space. Combo smoke and CO units are common, but their placement needs to follow the manufacturer’s specific guidance. CO tends to diffuse with indoor air, so height is less critical than smoke detectors, but avoiding dead air pockets and corners helps.
A good installer walks the homeowner through shutoffs: the gas valve, the furnace switch, the breaker, and how to replace a filter safely. If the system includes a condensate pump, show where it sits and how to clear the line if the pump alarms. The five-minute orientation reduces emergency calls and puts the homeowner in control of basic checks.
Special considerations in different homes
Every house adds its own wrinkles. Here are a few scenarios that change post-install inspections in practice:
- Older gravity-vented homes: When replacing a large, atmospheric furnace with a smaller, high-efficiency model, the old chimney becomes oversized for a remaining natural-draft water heater. The flue may need a properly sized liner to maintain draft and avoid condensation damage. Inspectors often flag this, but a proactive contractor addresses it during quoting and verifies it at final. Tight new construction: With air-sealed envelopes and powerful range hoods, makeup air can become the limiting factor. Even sealed-combustion appliances share space with bath fans and dryers. Pressure testing and balanced ventilation strategies keep the home neutral. This shows up during commissioning when doors are closed and fans are on. Attic installations in cold climates: Freeze protection for condensate and pan switches becomes critical. I like to see a secondary drain pan with its own float switch and a visible, insulated drain termination. During inspection, techs should pour water into the coil pan and confirm both drains and switches function. Multi-family units: Fire separation, shared chase venting, and common gas piping require more documentation. Inspectors usually scrutinize penetrations, fire collars, and appliance shutoffs closely. A neat, labeled installation speeds approval.
What a complete commissioning report looks like
At the end of a proper heating unit installation, you should receive a commissioning report. The best ones share a few common elements:
- Nameplate details and permit numbers. Measured electrical readings: line voltage, amp draws, and breaker size. Gas data: supply static and dynamic pressures, manifold pressure, and regulator settings. Combustion analysis results with draft measurements and flue CO in ppm. Airside readings: external static pressure, temperature rise, and blower settings selected. Refrigerant data for heat pumps: superheat, subcooling, outdoor and indoor temperatures during measurement. Safety device verification and notes about any simulated trips tested. Venting and condensate verifications, including photos of terminations and trap layout. Thermostat setup details: equipment configuration, staging, setpoint calibration, and balance points where applicable.
I’ve seen versions of this on a single page for simple furnaces and multi-page packets for complex dual-fuel systems. The length matters less than the specificity. When a tech heating unit installation writes “checked OK” without numbers, future you loses a valuable baseline.
How homeowners can prepare and follow up
Homeowners can make these inspections smoother with a few small steps. Clear space around the equipment, provide access to the electrical panel and gas meter, and have the thermostat powered and accessible. If you plan any renovations, mention them. A planned basement finish might change how the return is routed or where combustion air enters. After the system runs a week, note any odd noises, drafts, or frequent on-off cycling and share that with the installer. heating installation techniques The best contractors welcome a quick fine-tune visit because it keeps a good installation from becoming an average one.
If your heating replacement includes a brand with an app or remote diagnostics, register the equipment and enable alerts. Some manufacturers flag locked-out conditions or filter reminders before you notice a comfort change. Alarms do not replace inspections, but they help.
A word on timelines and cost
Not every market handles inspections the same way. In some cities, the permit inspection happens within a day or two of installation. In others, backlogs stretch to a week. Your contractor can coordinate this and may leave the old unit operational until the new one passes, or they may provide temporary heat if needed. Utility leak checks can add an extra appointment. Ask how these steps stack. Knowing the order helps you plan time at home.
Thorough post-install inspections add an hour or more of on-site time, sometimes longer if duct or gas pressure adjustments are needed. That time is not fluff. It is where safety and longevity get baked in. When you weigh quotes for heating system installation, look for explicit mention of commissioning and a checklist. The lowest number rarely includes it.
Red flags that warrant a second look
A few signs suggest the inspection phase was rushed or incomplete:
- No manometer, combustion analyzer, or static pressure readings taken, and no numbers recorded. Vent pipes without visible cement or screws, or terminations too close to windows or grade. A high-efficiency furnace with a dry, unprimed condensate trap, or a drain line running uphill. Breaker and wire sizes that do not match the equipment label or heater kit. Excessive blower noise, temperature rise outside the listed range, or frequent burner cycling during the first hour of operation.
If you notice any of these, call the contractor back before the first cold front tests the system in earnest.
The bottom line
A safe, well-tuned heating system is the product of careful installation paired with deliberate, measured verification. Combustion checks protect health. Electrical and overcurrent checks protect equipment. Venting and condensate checks protect the home. Airflow and control commissioning protect comfort and efficiency. Whether you are scheduling a straightforward heating unit installation or a complex heating replacement with duct changes and a smart thermostat, insist on the inspections and ask for the numbers. The day you need service, those numbers stop being technical trivia and become the roadmap that keeps your home warm, your energy bills sensible, and your family safe.